Pressure/Flow Control Valve
○ Outlet pressure control: 0.3~30bar; Inlet pressure: ≤40bar
○ -45℃~+180℃, G1/2~G2
○ Reduces and regulates pressure of liquid or gas systems, stable outlet pressure
○ Outlet pressure control: 0.2~35bar; Inlet pressure: ≤160bar
○ -60℃~+200℃, 316 Stainless Steel
○ Reduces and regulates pressure, mainly for gases, high sensitivity and stability
○ Outlet pressure control: 0.3~17bar; Inlet pressure: ≤160bar
○ -45℃~+180℃, 304 Stainless Steel
○ Reduces and regulates pressure, mainly for gases, stable outlet pressure
○ Outlet pressure control: 2~248bar; Inlet pressure: ≤350bar
○ -45℃~+180℃, 316 Stainless Steel
○ Reduces and regulates pressure, mainly for gases
○ Outlet pressure control: 2~206bar; Inlet pressure: ≤350bar
○ -45℃~+180℃, 304 Stainless Steel
○ Reduces and regulates pressure, mainly for gases
○ Ferrule fittings: pressure rating 315 bar
○ Needle valve: adjusts and shuts off flow, pressure rating 350 bar.
○ Safety relief valve: protects the pressure gauge; set pressure: 2–35 bar.
○ Radial/Axial Oil-Filled Vibration-Resistant Pressure Gauge: Pressure Rating 400/60 bar
○ Set pressure: 5~280bar; -50℃~+350℃
○ Connection: R1/4, R1/2, 1/4NTP
○ Limits the pressure of liquids or gase. When valve inlet pressure exceeds set pressure, the valve opens, reducing inlet pressure
○ Set pressure: 2~35bar; -45℃~+150℃
○ Connection: R1/4~1/2, G1/4~1/2, 1/4NPT
○ Compact design, limits pressure for liquid or gas systems, suitable for occasions with small discharge requirements
○ Set pressure: 4~230bar; Max. working pressure: 315bar
○ -40℃~+200℃; R1/4~R1
○ Used to stabilize pressure in liquid systems and prevent pressure from
○ Flow Range: 1~480L/min
○ 350bar, -35℃~+180℃
○ Regulates flow rate precisely, provides visual reference, with a locking mechanism to maintain selected opening. DVG-R also incorporates a check valve.
○ Flow Range: 2~460L/min
○ 40bar, -45℃~+180℃
○ Regulates flow rate precisely, provides visual reference, with a locking mechanism to maintain selected opening
○ DN 1.8~3mm, 160bar
○ Ferrule: 4mm, 6mm; Thread: G1/8~1/4
○ Regulates flow rate precisely, provides visual reference, with a locking mechanism to maintain selected opening
○ Constant Flow Range: 1~150L/min
○ 40bar, -45℃~+180℃
○ Regulates flow rate and maintains a constant output flow, mainly unaffected by system pressure fluctuations
○ 60bar, -35℃~+180℃, G1/2~G2
○ Input/output signal: 4~20mA;
○ Controls valve opening with 4~20mA signal, 304/316L stainless steel; Actuation time: 10~12s