KLF Stainless Steel Pressure Regulator
High-flow pressure reduction with G1/2 to G2 connections and model-specific outlet ranges
The KLF stainless steel pressure regulator reduces upstream pressure to a controlled downstream pressure in compatible liquid and gas lines. Its large-orifice design supports high-flow applications; the correct size depends on the required outlet pressure and operating flow.
Choose a G1/2 to G2 female connection, an X/A/B diaphragm configuration or C piston configuration, and a compatible seal. Use the model-specific inlet limit and flow curve rather than the series maximum alone.
Uses:
KLF pressure regulator is used for reducing and regulating pressure in fluid systems. It is connected in series in the pipeline to maintain a relatively stable outlet pressure. KLF features good pressure stability, applicable to water, oils, steam, air and other liquids and gases
Features
● Large orifice and high flow capacity, suitable for high-viscosity liquids like oil and paint;
● Balanced lift of the core contributes to little impact of changes in inlet pressure on outlet pressure;
● KLFs within four optional pressure ranges X/A/B feature diaphragm construction;those in range C feature a piston construction.
Technical Data
● Max. inlet pressure:40bar
● Outlet pressure control range: 0.3~30bar (see "Table of Technical Data")
● Medium temperature: -45℃~+180℃ (see "Application of Sealing Materials")
● Body material: 304/CF8 stainless steel
● Diaphragm and seal Material: see "Application of Sealing Materials"
● Pressure Gauge: 60mm outer diameter shock-resistant pressure gauge (stainless steel housing, copper core)
Note: If downstream flow is fully closed or extremely low, an exhaust branch is needed to reduce outlet pressure.
- Product Details
- 概要描述
- 文档下载
-
- Commodity name: KLF Stainless Steel Pressure Regulator
- Commodity ID: EG00720
- 小标题: High-flow pressure reduction with G1/2 to G2 connections and model-specific outlet ranges
KLF stainless steel pressure regulators reduce and regulate downstream pressure in compatible liquid and gas systems. Select G1/2 to G2 female connections and X, A, B or C pressure ranges. X/A/B models allow up to 25 bar inlet pressure; C models allow up to 40 bar. Confirm the seal, temperature and required flow for the selected configuration.
Application of Sealing Materials
Ordering Information


Table of Technical Data[mm]
Pressure - Water Flow Rate Curve Chart
I) Set Pressure Range: Type A, 0.5–6bar

II) Set Pressure Range: Type B, 0.5–12bar

How to select a KLF pressure regulator
Match the spring range to the outlet pressure
Select the required downstream pressure first, then check that the maximum inlet pressure is within the limit for that configuration:
- X: outlet adjustment 0.3-3 bar; maximum inlet pressure 25 bar; diaphragm construction.
- A: outlet adjustment 0.5-6 bar; maximum inlet pressure 25 bar; diaphragm construction.
- B: outlet adjustment 0.5-12 bar; maximum inlet pressure 25 bar; diaphragm construction.
- C: outlet adjustment 3-30 bar; maximum inlet pressure 40 bar; piston construction.
These adjustment ranges describe different configurations. A KLF with an X, A or B spring must not be selected using the 40 bar inlet limit of the C configuration.
Check flow at the required operating pressure
A high flow pressure regulator must be selected for the pressure available while the process is running. Select the chart for the exact connection size and spring range, identify the actual inlet-pressure curve, and read the flow at the required outlet pressure. Port size alone does not confirm flow capacity.
The published pressure-flow charts are for water. They should not be used directly to predict gas or viscous-oil flow. See how to read a pressure reducing valve flow curve for the three-step method.
Confirm materials, temperature and installation conditions
The KLF body is 304/CF8 stainless steel. NBR, FPM and EPDM seal options have different compatibility and temperature limits, and those limits also differ between diaphragm and piston configurations. Confirm the actual medium, concentration, normal and maximum temperature, and the complete operating pressure range before ordering.
If downstream flow is fully closed or extremely low, an outlet branch is needed to reduce the downstream pressure. Include this operating condition when discussing the installation. The regulator should not be assumed to provide a separate safety-relief function; see pressure reducing valves versus relief and overflow valves.
KLF selection questions
Can every KLF regulator accept 40 bar inlet pressure?
No. The listed maximum inlet pressure is 25 bar for X, A and B configurations, and 40 bar for C. Match the limit to the complete ordered model.
Which information is needed for sizing?
Provide the medium, connection size, minimum and maximum inlet pressure, required outlet pressure, target flow and units, operating temperature, and whether the downstream line can close completely.
Contact Eagle Fluid for KLF selection support, the applicable catalogue and a 3D model. Include your operating conditions so the selected spring, seal and size can be checked together.
Key words:- KLF
- pressure
- outlet
- diaphragm
- liquid
- temperature
- sealing material
- applicable to
- material
- see details
-
The KLF stainless steel pressure regulator reduces upstream pressure to a controlled downstream pressure in compatible liquid and gas lines. Its large-orifice design supports high-flow applications; the correct size depends on the required outlet pressure and operating flow.
Choose a G1/2 to G2 female connection, an X/A/B diaphragm configuration or C piston configuration, and a compatible seal. Use the model-specific inlet limit and flow curve rather than the series maximum alone.
Uses:
KLF pressure regulator is used for reducing and regulating pressure in fluid systems. It is connected in series in the pipeline to maintain a relatively stable outlet pressure. KLF features good pressure stability, applicable to water, oils, steam, air and other liquids and gasesFeatures
● Large orifice and high flow capacity, suitable for high-viscosity liquids like oil and paint;
● Balanced lift of the core contributes to little impact of changes in inlet pressure on outlet pressure;
● KLFs within four optional pressure ranges X/A/B feature diaphragm construction;those in range C feature a piston construction.Technical Data
● Max. inlet pressure:40bar
● Outlet pressure control range: 0.3~30bar (see "Table of Technical Data")
● Medium temperature: -45℃~+180℃ (see "Application of Sealing Materials")
● Body material: 304/CF8 stainless steel
● Diaphragm and seal Material: see "Application of Sealing Materials"
● Pressure Gauge: 60mm outer diameter shock-resistant pressure gauge (stainless steel housing, copper core)
Note: If downstream flow is fully closed or extremely low, an exhaust branch is needed to reduce outlet pressure.
Application of Sealing Materials
Ordering Information


Table of Technical Data[mm]
Pressure - Water Flow Rate Curve Chart
I) Set Pressure Range: Type A, 0.5–6bar

II) Set Pressure Range: Type B, 0.5–12bar

How to select a KLF pressure regulator
Match the spring range to the outlet pressure
Select the required downstream pressure first, then check that the maximum inlet pressure is within the limit for that configuration:
- X: outlet adjustment 0.3-3 bar; maximum inlet pressure 25 bar; diaphragm construction.
- A: outlet adjustment 0.5-6 bar; maximum inlet pressure 25 bar; diaphragm construction.
- B: outlet adjustment 0.5-12 bar; maximum inlet pressure 25 bar; diaphragm construction.
- C: outlet adjustment 3-30 bar; maximum inlet pressure 40 bar; piston construction.
These adjustment ranges describe different configurations. A KLF with an X, A or B spring must not be selected using the 40 bar inlet limit of the C configuration.
Check flow at the required operating pressure
A high flow pressure regulator must be selected for the pressure available while the process is running. Select the chart for the exact connection size and spring range, identify the actual inlet-pressure curve, and read the flow at the required outlet pressure. Port size alone does not confirm flow capacity.
The published pressure-flow charts are for water. They should not be used directly to predict gas or viscous-oil flow. See how to read a pressure reducing valve flow curve for the three-step method.
Confirm materials, temperature and installation conditions
The KLF body is 304/CF8 stainless steel. NBR, FPM and EPDM seal options have different compatibility and temperature limits, and those limits also differ between diaphragm and piston configurations. Confirm the actual medium, concentration, normal and maximum temperature, and the complete operating pressure range before ordering.
If downstream flow is fully closed or extremely low, an outlet branch is needed to reduce the downstream pressure. Include this operating condition when discussing the installation. The regulator should not be assumed to provide a separate safety-relief function; see pressure reducing valves versus relief and overflow valves.
KLF selection questions
Can every KLF regulator accept 40 bar inlet pressure?
No. The listed maximum inlet pressure is 25 bar for X, A and B configurations, and 40 bar for C. Match the limit to the complete ordered model.
Which information is needed for sizing?
Provide the medium, connection size, minimum and maximum inlet pressure, required outlet pressure, target flow and units, operating temperature, and whether the downstream line can close completely.
Contact Eagle Fluid for KLF selection support, the applicable catalogue and a 3D model. Include your operating conditions so the selected spring, seal and size can be checked together.
Previous page
Previous page
3D Diagrams and Sample Downloads