US-FL/01 Automatic Ferrule Pre-Installation Machine
Fully automatic ferrule pre-assembly machine
Uses:US-FL/01 ferrule pre-installation machine can be used for the pre-installation of Eagle ferrules (e.g. SR, ER, EG), and other DIN2353/ISO8434-1 compliant ferrules of PARKER, e.g. EO, EO2.
Features: US-FL/01 pre-installation machine adopts electric-hydraulic control and features easy operation and high efficiency.
Technical Data
● Working time: 5~8 s
● Overall dimensions: 510 mm*560 mm*280 mm
● Weight: 70 kg
● Power supply: 380 VAC (US-FL/01-380 V)
● Steel tube material: carbon steel and stainless steel
● Steel tube OD: ø6~42 mm
- Product Details
- 概要描述
- 文档下载
-
- Commodity name: US-FL/01 Automatic Ferrule Pre-Installation Machine
- Commodity ID: EG02000
- 小标题: Fully automatic ferrule pre-assembly machine
<span style="color:#af2039"> ○ </span> Specification: 6–42 mm <span style="color:#af2039"> ○ </span> Joint material: carbon steel, 9Cr18Mo
How to Use
1. Check the dimensions of the VSA pre-install connector.
2. Mount the GPA pre-install baffle and VSA connector.
3. Lubricate nut threads & ferrule outer surfaces with PASTE-L-2/3S;
slide nut & ferrule onto the steel tube in sequence (Fig.1)
4. Insert the tube with nut and ferrule into the pre-installation machine and press the tube against the connector.
5. Close the cover and press the start button.
6. Pre-installation process runs automatically
7. Open safety cover, remove tube; check ferrule piercing, tube bulge covering ferrule front edge (Fig.2)
Pre-install Tooling
1. Pre-install Baffle
2. Pre-install Connector
!! Note: If worn or deformed inner cone of the pre-install coupling causes scraps in assembly, check the dimensions every 50 ferrules based on the values of d and D in the table.
-
Uses:US-FL/01 ferrule pre-installation machine can be used for the pre-installation of Eagle ferrules (e.g. SR, ER, EG), and other DIN2353/ISO8434-1 compliant ferrules of PARKER, e.g. EO, EO2.
Features: US-FL/01 pre-installation machine adopts electric-hydraulic control and features easy operation and high efficiency.
Technical Data
● Working time: 5~8 s
● Overall dimensions: 510 mm*560 mm*280 mm
● Weight: 70 kg
● Power supply: 380 VAC (US-FL/01-380 V)
● Steel tube material: carbon steel and stainless steel
● Steel tube OD: ø6~42 mm
How to Use
1. Check the dimensions of the VSA pre-install connector.
2. Mount the GPA pre-install baffle and VSA connector.
3. Lubricate nut threads & ferrule outer surfaces with PASTE-L-2/3S;
slide nut & ferrule onto the steel tube in sequence (Fig.1)
4. Insert the tube with nut and ferrule into the pre-installation machine and press the tube against the connector.
5. Close the cover and press the start button.
6. Pre-installation process runs automatically
7. Open safety cover, remove tube; check ferrule piercing, tube bulge covering ferrule front edge (Fig.2)

Pre-install Tooling
1. Pre-install Baffle

2. Pre-install Connector

!! Note: If worn or deformed inner cone of the pre-install coupling causes scraps in assembly, check the dimensions every 50 ferrules based on the values of d and D in the table.