Manual ferrule pre-assembly machine

Uses: US-FL/01-MAN: Pre-assembly machine for BR/ER/SR/EG ferrules and other ferrules.

Features: US-FL/01-MAN realizes ferrule pre-installation with a manual hydraulic pump. US-FL/01-MAN features simple structural design and high reliability. US-FL/01-MAN ensures reliable connection of bite type fittings, reduce human errors and labor intensity and improve the efficiency of batch installation, and in particular it is valuable to the installation of large high pressure ferrules with a size exceeding Φ22.
Technical Data                                                                              
● Operation Mode: manual
● Overall dimensions: 400 mm*350 mm*200 mm
● Weight: 38 kg
● Steel tube material: carbon steel and stainless steel
● Steel tube OD: ø6~42 mm

  • Product Details
  • 概要描述
  • 文档下载
    • Commodity name: US-FL/01-MAN Manual Ferrule Pre-Installation Machine
    • Commodity ID: EG01990
    • 小标题: Manual ferrule pre-assembly machine

    <span style="color:#af2039"> ○ </span> Specification: 6–42 mm <span style="color:#af2039"> ○ </span> Joint material: carbon steel, 9Cr18Mo

    How to Use      

    1. Check dimension of pre-assembled adapter VS.
    2. Place into ferrule pre-install die (incl. baffle GP & adapter VS).
    3. Select pressure (recommended/empirical) per ferrule type, stainless steel tube grade & diameter.
    4. Lubricate nut threads & ferrule outer surfaces with PASTE-L-2/3S; slide nut & ferrule onto tube in sequence (Fig.1).
    5. Insert tube (with nut & ferrule) into pre-assembler; press tube against VS, nut back against baffle GP.
    6. Tighten manual pump relief knob, rock handle up/down to target pressure on gauge.
    7. Loosen relief knob, remove tube with pre-installed ferrule; check ferrule piercing, tube bulge covering ferrule front edge (Fig.2).

     

    Pre-install Tooling 
    1. Pre-install Baffle

     

    Model

    Series

    OD

    Model

    Series

    OD

    GP06

    L/S

    6

    GP20

    S

    20

    GP08

    L/S

    8

    GP22

    L

    22

    GP10

    L/S

    10

    GP25

    S

    25

    GP12

    L/S

    12

    GP28

    L

    28

    GP14

    S

    14

    GP30

    S

    30

    GP15

    L

    15

    GP35

    L

    35

    GP16

    S

    16

    GP38

    S

    38

    GP18

    L

    18

    GP42

    L

    42


    2. Pre-install Connector

     

    Model

    OD

    d

    Model

    OD

    d

    VS06L

    6

    8.1

    VS06S

    6

     

    8.1

    VS08L

    8

    10.1

    VS08S

    8

     

    10.1

    VS10L

    10

     

    12.3

    VS10S

    10

    12.3

    VS12L

    12

    14.3

    VS12S

    12

    14.3

    VS15L

    15

    17.3

    VS14S

    14

    16.3

    VS18L

    18

    20.3

    VS16S

    16

    18.3

    VS22L

    22

    24.3

    VS20S

    20

    22.9

    VS28L

    28

    30.3

    VS25S

    25

    27.9

    VS35L

    35

     

    38.0

    VS30S

    30

    33.0

    VS42L

    42

    45.0

    VS38S

    38

      

    41.0

    !! Note: If worn or deformed inner cone of the pre-install coupling causes scraps in assembly, check the dimensions every 50 ferrules based on the values of d and D in the table.

  • Uses: US-FL/01-MAN: Pre-assembly machine for BR/ER/SR/EG ferrules and other ferrules.

    Features: US-FL/01-MAN realizes ferrule pre-installation with a manual hydraulic pump. US-FL/01-MAN features simple structural design and high reliability. US-FL/01-MAN ensures reliable connection of bite type fittings, reduce human errors and labor intensity and improve the efficiency of batch installation, and in particular it is valuable to the installation of large high pressure ferrules with a size exceeding Φ22.
    Technical Data                                                                              
    ● Operation Mode: manual
    ● Overall dimensions: 400 mm*350 mm*200 mm
    ● Weight: 38 kg
    ● Steel tube material: carbon steel and stainless steel
    ● Steel tube OD: ø6~42 mm

How to Use      

1. Check dimension of pre-assembled adapter VS.
2. Place into ferrule pre-install die (incl. baffle GP & adapter VS).
3. Select pressure (recommended/empirical) per ferrule type, stainless steel tube grade & diameter.
4. Lubricate nut threads & ferrule outer surfaces with PASTE-L-2/3S; slide nut & ferrule onto tube in sequence (Fig.1).
5. Insert tube (with nut & ferrule) into pre-assembler; press tube against VS, nut back against baffle GP.
6. Tighten manual pump relief knob, rock handle up/down to target pressure on gauge.
7. Loosen relief knob, remove tube with pre-installed ferrule; check ferrule piercing, tube bulge covering ferrule front edge (Fig.2).

 

Pre-install Tooling 
1. Pre-install Baffle

 

Model

Series

OD

Model

Series

OD

GP06

L/S

6

GP20

S

20

GP08

L/S

8

GP22

L

22

GP10

L/S

10

GP25

S

25

GP12

L/S

12

GP28

L

28

GP14

S

14

GP30

S

30

GP15

L

15

GP35

L

35

GP16

S

16

GP38

S

38

GP18

L

18

GP42

L

42


2. Pre-install Connector

 

Model

OD

d

Model

OD

d

VS06L

6

8.1

VS06S

6

 

8.1

VS08L

8

10.1

VS08S

8

 

10.1

VS10L

10

 

12.3

VS10S

10

12.3

VS12L

12

14.3

VS12S

12

14.3

VS15L

15

17.3

VS14S

14

16.3

VS18L

18

20.3

VS16S

16

18.3

VS22L

22

24.3

VS20S

20

22.9

VS28L

28

30.3

VS25S

25

27.9

VS35L

35

 

38.0

VS30S

30

33.0

VS42L

42

45.0

VS38S

38

  

41.0

!! Note: If worn or deformed inner cone of the pre-install coupling causes scraps in assembly, check the dimensions every 50 ferrules based on the values of d and D in the table.

3D Diagrams and Sample Downloads