Check Valve Cracking Pressure vs Working Pressure
Release Date:
2026-10-27
Cracking pressure tells you when a check valve starts to open. Working pressure tells you the pressure limit of a particular valve configuration under its specified conditions. A valve rated to 400 bar does not need a 400 bar pressure difference to open.
These values answer different questions. To select a valve, also consider the flow required, the pressure drop available and how the valve behaves when flow stops.
Three pressure terms to keep separate
Term | What it describes | Selection question |
|---|---|---|
Cracking pressure | The forward pressure difference at which initial flow is detected under the specified test conditions. | Is enough differential pressure available to start opening the valve? |
Maximum working pressure | The published pressure limit for the selected model and operating conditions. | Is this model rated for the system pressure and temperature? |
Pressure drop during flow | The pressure difference between inlet and outlet while fluid passes through the valve. | Can the valve pass the required flow within the allowed pressure loss? |
Opening depends on the pressure difference
Use inlet and outlet pressures expressed on the same reference basis:
Forward differential pressure = inlet pressure - outlet pressure
For illustration, an inlet at 10 bar gauge and an outlet at 9.9 bar gauge give a forward differential of 0.1 bar. That is below a nominal 0.2 bar cracking pressure. If the outlet falls to 9.7 bar gauge, the differential becomes 0.3 bar, which exceeds that nominal setting.
This is a pressure-balance illustration, not a prediction of CPE flow. Exceeding the nominal opening value does not demonstrate that the valve is fully open or that it can deliver a required flow. Actual opening also depends on the applicable tolerance and operating conditions.
CPE cracking pressure options
The CPE catalogue lists the following options. Confirm the ordered model and configuration rather than selecting from the headline pressure rating alone.
Catalogue option | How it is presented | What to check |
|---|---|---|
0.2 bar | Standard cracking pressure. | Available differential at start-up and the required operating flow. |
0.5 bar | Listed for oils and other higher-viscosity liquids. | Fluid viscosity and temperature, including start-up conditions. |
3 bar | Optional cracking pressure. | Whether the circuit can provide the opening differential and operating pressure drop. |
Below 0.06 bar, -Q version | Listed for very low opening pressure, vacuum and very low gas-flow applications. | Required flow, sealing performance and the specific application conditions. |
For model selection and configuration details, review the CPE cracking pressure options. The 2026 catalogues list cracking pressure deviation as no greater than ±30%; confirm how the stated deviation applies to the ordered configuration, particularly a version specified by an upper limit such as -Q.
Applying the same checks to ATR
For a metal-seated application, review the ATR cracking pressure and pressure-temperature data. Apply these same checks using the selected ATR version, material and model rating. The CPE opening options and water-flow curves discussed in this guide should not be treated as ATR specifications. Temperature derating limits allowable working pressure; it is separate from pressure drop during flow.
Cracking pressure is not a flow-capacity rating
The CPE catalogue provides pressure drop-flow curves for the standard 0.2 bar version using water at 20°C. Use the curve for the relevant size, together with the model's Kv value, when checking the required operating point.
Do not transfer those water curves directly to gas service, a different spring setting or a liquid with different viscosity. For gas selection, provide inlet and outlet pressure, temperature and the reference conditions used for the stated flow. Ask for a calculation suitable for that medium.
Opening and resealing are separate checks
A check valve starts to open at its cracking condition, but its closing and resealing behaviour is a separate characteristic. Do not infer a resealing pressure or leakage guarantee from the opening setting. Provide the expected downstream pressure, operating cycle and allowable reverse leakage when asking for selection support.
What to include in an enquiry
- Medium, viscosity where relevant, and operating temperature range
- Inlet and outlet pressures at start-up and normal flow
- Required flow rate, units and reference conditions for gas
- Allowable pressure drop and required cracking pressure
- Connection standard, size, installation orientation and reverse-sealing requirements
Frequently asked questions
Is a lower cracking pressure always better?
No. It must match the available differential pressure and the application's opening and closing requirements. Select it with the flow and sealing conditions, rather than as an isolated number.
Does a 400 bar rating apply to every CPE size?
No. The catalogue pressure rating varies with size and connection. Check the exact model, operating temperature and seal configuration before ordering.
Other technical documents
Installation Guide for BR/ER/SR Ferrule Fittings
2026-06-18
Installation Guide for D-Series Double Ferrule Fittings
2026-06-18
Valve Dimensional Tolerances, Deviations, and Fits
2026-06-18
Stainless steel fittings and valve body dimensions
2026-06-18